Product Features

Four filtered functions

Technical Specifications of NSN

Overall Length:
3.625 inches
Overall Height:
2.500 inches
Mounting Slot Width:
0.257 inches
Body Length:
1.750 inches
Body Width:
1.380 inches
Body Height:
1.380 inches
Unthreaded Mounting Hole Diameter:
0.257 inches
Vibration Resistance Range In Hertz:
+10.0/+500.0
Vibration Resistance Range In Hertz:
+10.0 to 500.0
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
2.000 inches
Operating Tempurature Range:
-55.0/+85.0 degrees celsius
Operating Tempurature Range:
-55.0 to 85.0 degrees celsius
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference 1st function
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference 4th function
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference 2nd function
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference 3rd function
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Load Impedance Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 1st radio interference 1st function
Load Impedance Per Function:
50.0 ohms 2nd radio interference 2nd function
Load Impedance Per Function:
50.0 ohms 3rd radio interference 3rd function
Load Impedance Per Function:
50.0 ohms 4th radio interference 4th function
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference 1st function
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference 2nd function
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference 3rd function
Operating Current Rating Per Function In Amps:
10.0 1st radio interference
Operating Current Rating Per Function In Amps:
10.0 2nd radio interference
Operating Current Rating Per Function In Amps:
10.0 3rd radio interference
Operating Current Rating Per Function In Amps:
5.0 4th radio interference
Operating Current Rating Per Function In Amps:
10.0 2nd radio interference 2nd function
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference 1st function
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference 3rd function
Maximum Tempurature Rise:
25.0 degrees celsius
Inclosure Type:
Hermetically sealed
Mounting Facility Type And Quantity:
1 slot
Mounting Facility Type And Quantity:
1 unthreaded hole
Mounting Facility Type And Quantity:
1 unthreaded hole 1st function
Functional Terminal Type And Quantity:
1 connector, receptacle input 1st function
Functional Terminal Type And Quantity:
1 tab, solder lug ground 3rd function
Functional Terminal Type And Quantity:
4 tab, solder lug output 2nd function
Operating Voltage Rating And Type Per Function:
28.0 volts dc 4th radio interference 4th function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1st radio interference 1st function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 3rd radio interference 3rd function
Body Material:
Metal
Maximum Dielectric Withstanding Dc Voltage:
525.0 volts at sea level
Unpackaged Unit Weight:
200.0 grams
Style Designator:
Rectangular terminal/terminals on two surfaces
NSN:
5915-00-118-3955
Item Name:
Crt-emi Filter
Cage Code:
94117

Other Related Parts

Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC
Part Number:
292057P1
Cage Code:
94117
RNCC:
7
RNVC:
2
RNAAC:
SB
Status:
A
MSDS:
SADC:

  We Guarantee with Every Order

  •   100% Genuine Manufacturers Parts
  •   Every Product thoroughly Inspected
  •   Sales Record Retention of 7 years
  •   Fast Delivery
  •   HAZMAT Certified
  •   Global Shipping

Pricing & Availability

Submit this form for current pricing and availability quote on part number em1-f-0002 and/or cross reference parts.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:

We do not share or sell your information to anyone.
Privacy | Terms

Catalog Drilldown
--- Electrical And Electronic Equipment Components
------ Filters And Networks
--------- Radio Frequency Interfere Filters
------------ P/N EM1-F-0002

Best-Selling Products A collection of our most popular products

Last Updated: 12/24/2024